Modular Hydrogen Refueling Stations

Modular, expandable station architecture for heavy-duty or light-duty refueling station architecture with independently configureable compression, storage and dispensing capacities.

  • Fault-tolerant reliability through extensive failover interconnections between all subsystems.
  • Howden/Chart piston compressor designed specifically for hydrogen refueling under sporadic duty cycles.
  • Pre-cooled fills using a proprietary fueling-specific hydrogen cooling system.
  • Fully integrated with a single unified control system.
  • Available retail point of sale, fleet card support and remote station analytics.
  • Hyfluence equipment is engineered to level of functional safety and standards compliance unmatched in the industry.
Fuel Dispenser Specifications:
Fueling positionsSingle or dual
Hose orientationLane oriented or island oriented
Filling pressureH35 (350 bar) and/or H70 (700 bar)
Multi-pressure configurations available
Flow capacityStandard flow: 3.6 kg/min
High flow: 5.4 kg/min
H35 High flow: 7.2 kg/min
Fueling protocolsSAE J2601-1, SAE J2601-5 (MCF-HF-G)
Vehicle communicationsSAE J2799. Can operate without vehicle communications
MeteringCoriolis mass flow metering
User interface7″ color touch screen
PaymentsTap, chip and swipe functionality
Fleet card option available
Compression and capacity specifications:
Daily capacity (per compression moduleUp to 1600 kg/day
Max. capacity (per compression module)70 kg/hour
Inlet pressure range25 to 500 bar
Outlet pressure875 bar
Compressor typeHydraulically-driven piston, specifically developed for fueling duty
General system specifications:
Pre-coolingIn-house developed for refueling duty, integrated with dispenser
StorageOptimized through dynamic simulation of customer requirements
Monitoring and managementFull data logging and reporting, with optional web-based
system dashboard; remote management via secure
VPN; automated event reporting via email.
Operating temperature-15 ̊C to +40 ̊C, cold weather option available
Humidity20 to 95% Rh (non-condensing)
Dimensions, Dispenser0.9 x 1.0 x 2.7 meters (L x W x H)
Dimensions, Compression
Module
6.0 x 2.4 x 2.9 meters (L x W x H)
Dimensions, E-House
(1 per Compression Mod.)
3.6 x 2.4 x 2.9 meters (L x W x H)
Dimensions, Refrigeration
(1 per Dispenser)
5.0 x 1.6 x 4.8 meters (L x W x H)
CertificationsApplicable North American standards including
CSA HGV 4.1, 4.8, 4.9, NFPA 2, IEC 61508/61511, ADA, BNQ1784-000